Wet underfloor heating: how it works and where it suits
A wet system runs warm water through loops of plastic pipe buried in the floor. The loops meet at a manifold, a bank of valves with a flow gauge for each loop, fed by a mixing valve that blends the boiler flow down to the 35 to 45 degrees the floor needs. Each room or zone has its own loop and its own thermostat, so the bathroom can be warm at six in the morning while the spare room stays off.
It suits new floors best: extensions, ground floors being dug out and insulated, loft conversions and full renovations where the floor is coming up anyway. In a screed floor the pipe is clipped to insulation and the screed poured over it, giving the most even heat and the slowest response. In a timber floor the pipe sits in aluminium spreader plates between the joists, or in a low-profile routed board over the existing floor where height is tight. For retrofit into a London flat with a finished floor, a low-profile overlay system at 15 to 20 mm is often the answer.